FLAMECO INDUSTRIES PRODUCTS
Leading Innovators of Natural Draft Burners Since 1980
TYPES OF NATURAL DRAFT BURNERS
NATURAL DRAFT BURNER TYPES
Side Mount
Recommended BTU Range: 50,000 – 2,000,000 BTU/hr
Recommended for Firetube Sizes: 4” – 30”
Recommended Use: Used for clearance & ease of access.

DESIGN OF NATURAL DRAFT BURNER
NATURAL DRAFT BURNER DESIGNS
Current supported Natural Draft Burner Designs
Design | O-Type | Hinge Type | Box Type | Side Mount |
|---|---|---|---|---|
Standard | ||||
Reduced Noise | ||||
Air Control Reduced Noise | ||||
Push-Pull Air Control Reduced Noise | ||||
Push-Pull Air Control Low Noise | ||||
Low Noise | ||||
Elevated Air Supply | ||||
Elevated Air Supply Reduced Noise | ||||
Elevated Air Supply Low Noise | ||||
Elevated Air Supply Rotary Air Control | ||||
Cam Lock | ||||
Air Control | ||||
Air Control Low Noise |

Elevated Air Supply
A safety system designed to burn off excess or unusable gases at high elevations, minimizing fire hazards.
Note:
Reduced & Low Noise
An insulated design targeted satisfaction of site noise requirements. The Reduced Noise is partially insulated, making it a more cost-effective option when extreme noise reduction is not required.
The Low Noise design is fully insulated with the addition of a baffle plate. This design is the most effective noise reduction that Flameco has to offer. This is the ideal choice when the operational site is near local communities.
Note:
Air Control
A pneumatic push-pull, or rotating, system that controls the primary air flow draft. This is the design to choose when you want to optimize draft through air supply while also reducing the number of start-up cycles.
Note:
Combining Designs
Our engineering expertise and manufacturing capabilities enable us to produce a variety of design combinations specifically to meet customer requirements.
Reference the Burner Body and Design matrix above to find the right product for you.
Note:
ENHANCEMENT OF NATURAL DRAFT BURNER
NATURAL DRAFT BURNER ENHANCEMENT OPTIONS
Options that are included in the manufacturing design and production of the natural draft burner.
Enhancement | O-Type | Hinge Type | Box Type | Side Mount |
|---|---|---|---|---|
6” x 6” Access | ||||
Lifting Lugs | ||||
Manway | ||||
Purge Fan | ||||
Quick-Clamps | ||||
UV Sight Tube | ||||
Welded Flange Nuts | ||||
XFMR (Transformer Bracket) | ||||
Cam Lock | ||||
Ignition Module Bracket | ||||
Cam Lock |
6” x 6” Access:
Enables easy access to internal piping, main burner, and pilot assemblies.
Lifting Lugs:
Provide additional safety and stability with transporting, mounting, or securing the burner. This option is recommended when the burner is to be mounted more than 4 ft from the ground.
Manway:
Manway covers are attached by nuts & bolts, providing easy access to internal components.
Purge Fan:
Purge fans push air through the firetube and stack, eliminating residual gas.
Transformer Bracket (XFMR):
Transformer Brackets (XFMR) are made to mount inside the housing.
Ignition Module Bracket:
Ignition module brackets securely mount burner management systems for reliable installation.
Quick-Clamps:
This design was created to provide technicians with ease of access to burner internals. Rather than nuts and bolts, quick-clamps are welded to the housing for seamless maintenance process.
UV Sight Tube:
The UV Sight Tube enables automatic flame monitoring for the burner.
Welded Flange Nuts
Aluminum nuts are welded inside the housing for ease of mounting and removing the flame arrestor. This option is selected when ease of access is a priority to field and service technicians.

ADD-ON OF NATURAL DRAFT BURNER
NATURAL DRAFT BURNER ADD-ON OPTIONS
Options that are produced and attached as a separate part to the natural draft burner.
Add-On | O-Type | Hinge Type | Box Type | Side Mount |
|---|---|---|---|---|
Companion Flange | ||||
Extension Nipples | ||||
Extension Spool | ||||
Gasket | ||||
Manual Secondary Air Control Spool | ||||
Return Flu Gas | ||||
Threaded Vent Arrestor | ||||
Transformer Bracket | ||||
Ignition Module Bracket |
Plate Flange:
Mounting flange adapter that connects the burner flange to unique customer requirements.
Extension Nipple:
A custom threaded pipe to extend the nozzle/flame into the firetube to the proper and safe depth. Ask for this addition when the nozzle is not placed within the bath solution (4" - 6".)

Extension Spool:
A mounting spool that is used to extend the flame arrestor past an obstruction. Recommended when the stack overhang exceeds the standard or when retrofitting the current unit.
Manual Secondary Air Control Spool:
Control secondary airflow going into the firetube. This product is aimed at retaining heat in the firetube and reducing cycle times.
Return Flue Gas:
Ideal for units that have the intention of returning Flue Gas for reuse. This product is also recommended for extreme weather conditions.
Threaded Vent Arrestor
Designed for end-of-line vertical venting, this arrestor enables unrestricted airflow while providing flame protection for storage tanks and atmospheric vent lines. Ideal for low-pressure systems, it prevents flame ingress without impeding normal breathing and venting operations.
Gasket:
Recommended for all flange connections. The Gasket provides a seamless seal aimed at preventing air or liquid from entering or exiting the flange connection.